Shop

HB101

Specifications

  • Voltage ranges: 22vdc to 26vdc (Rated voltage: 24vdc)
  • Power and current consumption: 0.5W, 18ma@26vdc(maximum)
  • Sound levels at 30° intervals from 15° to 165°: >85dB/m (minimum)
  • Main sound frequency: 4500hz
    Description
  • The Electric Alarm Bell of notification appliances offers a wide range of Sound, for wall applications, indoors. They are designed to be used in 24 volt DC systems.

 

HC102B

Conventional Call Point Pull Down type
Specifications

  • Operating Voltage Range: 9 to 28VDC Volts
  • Alarm Resistance: 470ohm/1W
  • Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
  • Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
  • Dimensions: Length 140mm, Width 105mm, Depth 45mm
    Description
  • The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system.

HC202B

Addressable Call Point Pull Down type
Specifications

  • Operating Voltage Range: 9~28VDC Volts
  • Alarm Current: 5 mA @ 24 VDC
  • Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
  • Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
  • Dimensions: 140mm L x 105mm W x 45mm H
    Description
    The addressable manual call point designed for addressable fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. So the addressable manual call point is only used with addressable fire alarm control panel, it is forbidden to be used to other system.

HD101-B

Conventional Smoke Detector
specifications

  • Operating Voltage Range: 16 to 28VDC Volts Non-polarized
  • Standby Current: 60μA @ 28 VDC(Maximum)
  • Alarm Current (LED on: ) 30mA @ 28 VDC(Maximum)
  • Adjustable Sensitivity: 0.1 to 0.3dB/m
  • Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
    Description
  • This detector can be used in all areas where photoelectric smoke detector is required. It is suited for fires ranging from smoldering to flaming fires. This detector uses a state of-the-art optical sensing chamber, it is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible for indication of status. In the normal condition the LEDs flash red every 5 seconds. When the detector senses smoke goes into pre-alarm sensitivity the LEDs will flash red every 1 second. When the detector senses smoke and goes into alarm the LEDs will latch on red. The alarm can be reset only by a momentary power interruption.

 

HD102-B

Conventional Heat Detector
Specifications

  • Operating Voltage Range: 16 to 28VDC Volts Non-polarized
  • Standby Current: 40μA @ 28 VDC(Maximum)
  • Alarm Current (LED on: ) 30mA @ 28 VDC(Maximum)
  • Temperature Class: A2R
  • Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
    Description
    This detector can be used in all areas where heat detector is required. It is suited for fires ranging from heat to flaming fires. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible for indication of status. In the normal condition the LEDs flash red every 5 seconds. When the detector senses heat goes into pre-alarm sensitivity the LEDs will flash red every 1 second. When the detector senses heat and goes into alarm the LEDs will latch on red. The alarm can be reset only by a momentary power interruption.

 

HD103-B

Conventional MULTI Detector
Specifications

  • Operating Voltage Range: 9 to 28VDC Volts Non-polarized
  • Standby Current: ≤60μA @ 24 VDC
  • Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC
  • Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
  • Operating Temperature Range: 14°F to 120°F (-10°C to 49°C)
    Description
  • The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

 

HD104

Conventional UV Flame Detector
Specifications

  • Operating Voltage Range: 12 to 28 VDC Volts
  • Standby Current: ≤10 mA @ 24 VDC
  • Alarm Current: ≤40 mA @ 24 VDC
  • Spectrum: 180~290nm
  • Detection Angle: 120 degree
    Description
  • The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust- resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.

 

HD105

Conventional Gas Detector
Specifications

  • Self diagnostic function by MCU intelligent software.
  • Excellent reliability & high stability.
  • High quality durable sensor.
  • Loud 85dB alarm and LED warning light.
  • Ideal for all kitchens.
    Description
  • The gas alarm is designed for single station use. Small and compact, the design and color makes it ideal for use in the home, small commercial properties, and recreational vehicles. It is intended to detect leakage of natural gas (methane gas), town gas, and bottled gas (propane gas). The unit is designed for DC wire-in applications. The gas alarm can be mounted high (for methane gas) or low (for propane (LPG) gas). It is equipped with a sturdy metal mounting bracket for quick, easy, and secure installation.

 

HD106

Conventional Beam Detector

100m Monitoring Area:

1400m2, Maximum Length of

Optical Pathway: 8m to 100m

Specifications

  • 24Voltage power supply
  • 470 Ohm Alarm Resistance
  • Detection Range from 8mt to 100mt Distance, Width 14meter
  • Operating current: standby 1mA, Alarm Current 2.5mA
  • Operating environment: Temperature -10 to 60 degree

HD201B

Optical Addressable Smoke Detector

  • operating Voltage Range: 15 to 28 VDC
  • Standby Current: 400μA @ 24 VDC (one communication every 5 seconds with LED blink enabled)
  • Maximum Alarm Current (LED on): 7 mA @ 24 VDC
  • Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
  • Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
    Description
  • The detector is plug-in type photoelectronic smoke and heat sensors with addressable analog communications. The sensors transmit an analog representation of smoke density or temperature over a communication line to a control panel. Inside MCU’s EEPROM keep the sensor’s address that can be set by a portable Address setting device. Two LEDs on the sensor are controlled by the panel to indicate sensor status. The detector require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.