Showing 85–96 of 314 results
Shop
HD202B
Addressable Heat Detector
Specifications
- Height: 2.2 ̋ (55 mm) installed in Base
- Diameter: 4.0 ̋ (103 mm)
- Weight: 5.5 oz. (155 g)
- Installation Temperatures: 14°F to 122°F (-10°C to50°C)
- Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing
Description - The detector is intelligent sensors that utilize a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open area protection with 50 foot spacing capability. The detector is a rate-of-rise temperature sensor with 135°F fixed temperature alarm. Inside MCU’s EEPROM keep the sensor’s address that can be set by a portable Address setting device. Two LEDs on each sensor light to provide 360° visibility of the sensor indication. The LEDs can be latched ON by code command from the panel for an alarm indication. The LEDs can also be unlatched to the normal condition by code command. The detector requires compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.
HD203B
Addressable Multi Sensor (Smoke and Heat)
Specifications
- Operating Voltage Range: 15 to 28 VDC
- Standby Current: 400μA @ 24 VDC (one communication every 5 seconds with LED blink enabled)
- Maximum Alarm Current (LED on: ) 7 mA @ 24 VDC
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
- Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
Description
The detector is plug-in type photoelectronic smoke and heat sensors with addressable analog communications. The sensors transmit an analog representation of smoke density or temperature over a communication line to a control panel. Inside MCU’s EEPROM keep the sensor’s address that can be set by a portable Address setting device. Two LEDs on the sensor are controlled by the panel to indicate sensor status. The detector require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.
HM201-C
Addressable Interface module
General Description:
The interface module can be installed in a single gang
junction box directly behind the monitored unit. Its small
size and light weight allow it to be installed without rigid
mounting. The module is intended for use in addressable,
two-wire systems where the individual address of each
module is written inside the MCU’s EEPROM by the
addressable programmer.
The Interface module allows intelligent panels to interface
and monitor 2-wire conventional detectors. The module is
addressed through the communication line of an intelligent
system. It transmits the status of one zone of 2-wire
detectors to the fire alarm control panel. Status conditions
are reported as normal, open, or alarm. The interface
module supervises the zone of detectors and the
connection of the external power supply.
HM201-I
Short circuit isolator Module
- Specifications
- Nominal Operating Voltage: 15 to 28 VDC
- Short Circuit Current Limitation: >700 mA @ 24 VDC
- Short Loop Resistance: <50Ω
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
- Operating Temperature Range: -10°C to50°C
Description
The Short Circuit Isolator Modules enable part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator turns on during a short circuit condition. The module will automatically restore the entire communications loop to the normal condition when the short circuit is removed.
HM201-R
Addressable relay (Output-Control) module
Specifications
- Nominal Operating Voltage: 15 to 28 VDC
- Standby Current: ≤1mA @ 24 VDC
- Maximum Alarm Current (LED on: ) ≤5 mA @ 24 VDC
- Maximum(NAC): Regulated 24VDC
- Max Relay Contacts Current Ratings: 2A/DC24V, 1A/220VAC
Description
The Relay Output Modules are intended for use in addressable, two wire systems, where the individual address of each module is programmed in the MCU’s Flash memory. This module is used to switch an external power supply, which can be a DC power supply or an audio amplifier (up to 80 VRMS), to notification appliances. It also supervises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN, or SHORT CIRCUIT.
HM201-S
Addressable Input module
Specifications
- Nominal Operating Voltage: 15 to 28 VDC
- Standby Current: ≤1mA @ 24 VDC
- Maximum Alarm Current (LED on: ) ≤5 mA @ 24 VDC
- EOL resistance: 4.7K Ohms
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Description - The module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The module is intended for use in addressable, two-wire systems where the individual address of each module is writhen inside the MCU’s EEPROM. It provides a two-wire initiating circuit for normally open contact fire alarm and security devices.
HP101-16 (Without Battery)
16 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,
Maximum number can be connected 30 detector to area, UL (864) listed From Intertek
- 16 conventional input zones.
- 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
- The panel comes with a 3 amp power supply.
- Dedicated alarm and trouble relays.
- 1 RS485 can be able to connect repeaters.
- Description
- The fire alarm control panels ( 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.
HP101-2
2 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power 28V, 1port premium power 28V, Maximum number can be connected 30 detector to area, UL (864) listed From Intertek
HP101-4 (Without Battery)
4 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,
Maximum number can be connected 30 detector to area, UL (864 cd) listed From Intertek
Specifications
- 4 conventional input zones.
- 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
- The panel comes with a 3 amp power supply.
- Dedicated alarm and trouble relays.
- 1 RS485 can be able to connect repeaters.
- Description
- The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.