Showing 1–12 of 22 results
HP101-2
2 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power 28V, 1port premium power 28V, Maximum number can be connected 30 detector to area, UL (864) listed From Intertek
HP101-4-EC
4 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,
Maximum number can be connected 30 detector to area, UL (864 cd) listed From Intertek
HP101EP-4
A Conventional Economy Alarm Panel is a conventional fire alarm control panel designed to efficiently manage conventional fire alarm systems, providing reliable monitoring of circuits, detectors, and manual call points, with the ability to connect sounder devices and various output systems.
HP101-4 (Without Battery)
4 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,
Maximum number can be connected 30 detector to area, UL (864 cd) listed From Intertek
Specifications
- 4 conventional input zones.
- 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
- The panel comes with a 3 amp power supply.
- Dedicated alarm and trouble relays.
- 1 RS485 can be able to connect repeaters.
- Description
- The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.
HP101-8 (Without Battery)
8 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V, Maximum number can be connected 30 detector to area, UL (864) listed From Intertek
Specifications
- 8, conventional input zones.
- 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
- The panel comes with a 3 amp power supply.
- Dedicated alarm and trouble relays.
- 1 RS485 can be able to connect repeaters.
- Description
- The fire alarm control panels (8 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.
HP101-16 (Without Battery)
16 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,
Maximum number can be connected 30 detector to area, UL (864) listed From Intertek
-
- 16 conventional input zones.
- 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
- The panel comes with a 3 amp power supply.
- Dedicated alarm and trouble relays.
- 1 RS485 can be able to connect repeaters.
- Description
- The fire alarm control panels ( 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.
GA-504
Detect all sorts of combustible gases, natural gas (methane), bottled gas (propane),
LPG (Liquefied petroleum Gas), LNG (Liquefied natural gas), coal gas, including town gas.
Easy to install, mounting bracket included.
Loud 85dB alarm and LED warning light. High quality durable sensor.
Self-diagnostic function by MCU intelligent software.
Excellent reliability & High stability.
Ideal for all kitchens.
HB101
Specifications
- Voltage ranges: 22vdc to 26vdc (Rated voltage: 24vdc)
- Power and current consumption: 0.5W, 18ma@26vdc(maximum)
- Sound levels at 30° intervals from 15° to 165°: >85dB/m (minimum)
- Main sound frequency: 4500hz
Description - The Electric Alarm Bell of notification appliances offers a wide range of Sound, for wall applications, indoors. They are designed to be used in 24 volt DC systems.
HC102B
Conventional Call Point Pull Down type
Specifications
- Operating Voltage Range: 9 to 28VDC Volts
- Alarm Resistance: 470ohm/1W
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
- Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
- Dimensions: Length 140mm, Width 105mm, Depth 45mm
Description - The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system.
HD101-B
Conventional Smoke Detector
specifications
- Operating Voltage Range: 16 to 28VDC Volts Non-polarized
- Standby Current: 60μA @ 28 VDC(Maximum)
- Alarm Current (LED on: ) 30mA @ 28 VDC(Maximum)
- Adjustable Sensitivity: 0.1 to 0.3dB/m
- Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
Description - This detector can be used in all areas where photoelectric smoke detector is required. It is suited for fires ranging from smoldering to flaming fires. This detector uses a state of-the-art optical sensing chamber, it is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible for indication of status. In the normal condition the LEDs flash red every 5 seconds. When the detector senses smoke goes into pre-alarm sensitivity the LEDs will flash red every 1 second. When the detector senses smoke and goes into alarm the LEDs will latch on red. The alarm can be reset only by a momentary power interruption.
HD102-B
Conventional Heat Detector
Specifications
- Operating Voltage Range: 16 to 28VDC Volts Non-polarized
- Standby Current: 40μA @ 28 VDC(Maximum)
- Alarm Current (LED on: ) 30mA @ 28 VDC(Maximum)
- Temperature Class: A2R
- Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
Description
This detector can be used in all areas where heat detector is required. It is suited for fires ranging from heat to flaming fires. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible for indication of status. In the normal condition the LEDs flash red every 5 seconds. When the detector senses heat goes into pre-alarm sensitivity the LEDs will flash red every 1 second. When the detector senses heat and goes into alarm the LEDs will latch on red. The alarm can be reset only by a momentary power interruption.