Fire Alarm System

HP201-2EP

Features

  • Two onboard detection loops with maximum 500 addressable devices, such as addressable smoke detector,
  • heat detector, call point, input module, output module, interface module, sounder strobe and remote repeater etc.
  •  Loop circuit can be set to Class A or Class B wiring communication modes.
  •  One onboard free Fixed 24 voltage output.
  •  One onboard free Re-settable 24 voltage output.
  •  Two notification Appliance Circuits(NACs).
  •  One fire relay output.
  •  One fault relay output.
  •  One auxiliary relay output.
  •  One RS-485 interface for remote repeater or the other display device.
  •  Six onboard fixed alarm functional keys (Evacuate Start , Evacuate Stop,Silence Buzzer,Reset System, Test Lamp and Control Mode).
  •  Full navigation keys & full numeric keypad.
  •  Twelve onboard functional LED indicators for different panel states.
  • Sixteen fire zones LED indicators.
  • 999fireeventlogrecords,999faulteventlogrecordsand999theothereventlogrecords.
  • Realtime clock.

HP201-4

Features:

  • 4 on board detection loops with maximum 240 devices per loop Total 960 devices(HST protocol).
  • 2 onboard programmable monitored conventional sounder lines.
  • 2 onboard programmable relays.
  • 2 onboard programmable dry contact inputs.
  • 1 onboard programmable 24 voltage output.
  • 2 onboard free 24 voltage output.
  • 4 onboard fixed alarm functional keys
  • 1 onboard fixed evacuate key.
  • 2 onboard programmable keys.
  • Full navigation keys& full numeric keypad.
  • 14 onboard functional LED indicators.
  • 480 zones with 16 onboard zonal LED indicators.
  • 2000 event log records.
  • Large graphical display(240X128pixels).
  • 1RS-232interface for PC panel con_guration tool.
  • 1RS 485 communication port for repeater
  • Real timeclock.

HP101-2

2 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power 28V, 1port premium power 28V, Maximum number can be connected 30 detector to area, UL (864) listed From Intertek

HP101-4-EC

4 Zones Fire Alarm Control Panel

2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,

Maximum number can be connected 30 detector to area, UL (864 cd) listed From Intertek

HP101EP-4

HP101EP-4

A Conventional Economy Alarm Panel is a conventional fire alarm control panel designed to efficiently manage conventional fire alarm systems, providing reliable monitoring of circuits, detectors, and manual call points, with the ability to connect sounder devices and various output systems.

HP101-4 (Without Battery)

4 Zones Fire Alarm Control Panel

2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,

Maximum number can be connected 30 detector to area, UL (864 cd) listed From Intertek
Specifications

  • 4 conventional input zones.
  • 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
  • The panel comes with a 3 amp power supply.
  • Dedicated alarm and trouble relays.
  • 1 RS485 can be able to connect repeaters.
  • Description
  • The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.

HP101-8 (Without Battery)

8 Zones Fire Alarm Control Panel

2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V, Maximum number can be connected 30 detector to area, UL (864) listed From Intertek

Specifications

  • 8, conventional input zones.
  • 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
  • The panel comes with a 3 amp power supply.
  • Dedicated alarm and trouble relays.
  • 1 RS485 can be able to connect repeaters.
  • Description
  • The fire alarm control panels (8 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.

HP101-16 (Without Battery)

16 Zones Fire Alarm Control Panel

2port sounder, 2port fire relay output, 1port fault relay output, 1Port resettable power28V, 1port premium power 28V,

Maximum number can be connected 30 detector to area, UL (864) listed From Intertek

  • 16 conventional input zones.
  • 2 notification appliance circuits (NAC, Sounder) with built-in synchronization for ANSI 3.41and Gentex.
  • The panel comes with a 3 amp power supply.
  • Dedicated alarm and trouble relays.
  • 1 RS485 can be able to connect repeaters.
  • Description
  • The fire alarm control panels ( 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, photoelectric-thermal and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device.

HP102-4 (Without Battery)

Conventional Fire Fighting panel

  • Certificate of Constancy of Performance from Intertek0359-CPR-00611
  • One Form-A Alarm Relay
  • One Form-A Trouble Relay
  • Two Form-A Stage Relay
  • Max 30 conventional detectors in one
  • Can connect max 32 repeater panels by RS485 communication port
    Specifications

    • Weight: 5kg
    • Power supply rating: 3 Amps total including battery charge 28V +/- 2V
    • Fire relay contact rating: 2A /30VDC maximum for each
    • Number of detectors per zone: ≤30 PCS conventional detectors
    • Sounder circuit end of line: 10K±5% 1/2 Watt resistor
    • Description
    • The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems – Control and Indicating Equipment and EN12094-1 Fixed firefighting systems – Components for gas extinguishing systems – Part 1: Requirements and test methods for electrical automatic control and delay devices. The control equipment is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision. Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.

HP201-4 (Without Battery)

Electronic Addressable Intelligent Fire Alarm Control Panel (Including 1 Loop LK401 Loop Card) 1-4 Loops, 250-1000 Node Capacity, Repeater Connection, By LE505 Loop Extension Module can be extended to 16 Loops, Metal Case, 128×64 Graphic LCD Display, 16 Zone Lamps, 250 Zones, Programmable Zone Contents, Alarm and Error Relay Outputs, Supervise Siren Output, 3 Open Collector Outputs, Event Log,Turkish

and EnglishLanguage,RS485 Serial Interface, Real Time Clock, EN54-2/4 Compatible. Dimensions: 34,5x36x10,5cm

HP201-2 (Without Battery)

Professional Addressable Panel 2Loop each Loop 247 Address can be Programmed by Computer
Large Display, Switched mode Power supply Programmable sounder and Relays

Specifications

  • 2 onboard detection loops with maximum 250 devices per loop (HST protocol).
  • 2 onboard programmable monitored conventional sounder lines.
  • 3 onboard programmable relays.
  • 3 onboard programmable dry contact inputs.
  • 1 onboard free 24 voltage output
  • Description
  • HST-HP201-2 is an addressable fire alarm control panel capable of connecting up to 250 HST addressable devices per loop. With its extra large graphical display, it configures almost all panel settings via its very simple interface via HST (RINGER). It stores almost all different actions monitored up to 4000 event log records. HST-HP201-2 covers all small to medium size fire detection system needs.