Showing 1–12 of 22 results
HP201-4 (Without Battery)
Electronic Addressable Intelligent Fire Alarm Control Panel (Including 1 Loop LK401 Loop Card) 1-4 Loops, 250-1000 Node Capacity, Repeater Connection, By LE505 Loop Extension Module can be extended to 16 Loops, Metal Case, 128×64 Graphic LCD Display, 16 Zone Lamps, 250 Zones, Programmable Zone Contents, Alarm and Error Relay Outputs, Supervise Siren Output, 3 Open Collector Outputs, Event Log,Turkish
and EnglishLanguage,RS485 Serial Interface, Real Time Clock, EN54-2/4 Compatible. Dimensions: 34,5x36x10,5cm
HP201-2 (Without Battery)
Professional Addressable Panel 2Loop each Loop 247 Address can be Programmed by Computer
Large Display, Switched mode Power supply Programmable sounder and Relays
Specifications
- 2 onboard detection loops with maximum 250 devices per loop (HST protocol).
- 2 onboard programmable monitored conventional sounder lines.
- 3 onboard programmable relays.
- 3 onboard programmable dry contact inputs.
- 1 onboard free 24 voltage output
- Description
- HST-HP201-2 is an addressable fire alarm control panel capable of connecting up to 250 HST addressable devices per loop. With its extra large graphical display, it configures almost all panel settings via its very simple interface via HST (RINGER). It stores almost all different actions monitored up to 4000 event log records. HST-HP201-2 covers all small to medium size fire detection system needs.
HP306AR (Without Battery)
Full Function Repeater:
* Full functional active addressable repeater
* 2 wires communication with addressable panel
* Repeater main power different than addressable panel power* Repeater backup battery
* Repeater backup battery fault warning
* Repeater Active commands (Silence Buzzer, Silence Alarm, Resound Alarm, Fire reset ,System Evacuate)
* Panel Faults LEDs
* Panel Zone LEDs indicator
HP201-1 EC
Economic Addressable Panel 1Loop, Maximum 250 Addressable devices , Large Display,
free 24 voltage output ,
onboard fixed alarm functional keys ,
onboard functional LED indicators for different panel states , 16 fire zones LED indicators
Including two Short circuit isolator Module
ABS-YW11
Auto-sensingtype two in one smoke and heat detector tester Smoke test 450-800 detectors with battery full charged heat test 400 detectors with battery full charged
Smoke source environmentally friendly smoke liquid Standard length 4.8 meters
Tester material aluminum
HC202B
Addressable Call Point Pull Down type
Specifications
- Operating Voltage Range: 9~28VDC Volts
- Alarm Current: 5 mA @ 24 VDC
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
- Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
- Dimensions: 140mm L x 105mm W x 45mm H
Description
The addressable manual call point designed for addressable fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. So the addressable manual call point is only used with addressable fire alarm control panel, it is forbidden to be used to other system.
HD201B
Optical Addressable Smoke Detector
- operating Voltage Range: 15 to 28 VDC
- Standby Current: 400μA @ 24 VDC (one communication every 5 seconds with LED blink enabled)
- Maximum Alarm Current (LED on): 7 mA @ 24 VDC
- Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
- Operating Temperature Range: 14°F to 122°F (-10°C to50°C)
Description - The detector is plug-in type photoelectronic smoke and heat sensors with addressable analog communications. The sensors transmit an analog representation of smoke density or temperature over a communication line to a control panel. Inside MCU’s EEPROM keep the sensor’s address that can be set by a portable Address setting device. Two LEDs on the sensor are controlled by the panel to indicate sensor status. The detector require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.
HD202B
Addressable Heat Detector
Specifications
- Height: 2.2 ̋ (55 mm) installed in Base
- Diameter: 4.0 ̋ (103 mm)
- Weight: 5.5 oz. (155 g)
- Installation Temperatures: 14°F to 122°F (-10°C to50°C)
- Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing
Description - The detector is intelligent sensors that utilize a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open area protection with 50 foot spacing capability. The detector is a rate-of-rise temperature sensor with 135°F fixed temperature alarm. Inside MCU’s EEPROM keep the sensor’s address that can be set by a portable Address setting device. Two LEDs on each sensor light to provide 360° visibility of the sensor indication. The LEDs can be latched ON by code command from the panel for an alarm indication. The LEDs can also be unlatched to the normal condition by code command. The detector requires compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.